Troubleshooting a Powermax 0-30 Fault Code

For metal workers who need to easily and reliably gouge and cut metal up to 38 mm (1-1/2″), Powermax® is a line of seven portable, professional-grade plasma systems that are designed for maximum productivity. Unlike other metal removal methods or competitive plasma brands, industry-leading Powermax systems allow customers to tackle any job by offering the most extensive manual and automated metal cutting and gouging capabilities.
This short video will help you to identify the symptoms of an 0-30 error for the Powermax® product line, where to locate the fault code on the machine, and some possible solutions.
0:00 - Introduction
0:46 - 0-30 Fault Code Symptoms
1:19 - Different 0-30 Faults
1:42 - Low-amperage machine fault display (30 AIR, 30 XP, 45 XP)
2:02 - High-amperage machine fault display (65, 85, 105, 125)
2:38 - Resolving Fault - Consumable inspection and replacement
3:07 - Resolving Fault - Torch or power supply damage
3:25 - Continuing 0-30-1 fault - Perform a gas test
4:43 - Conclusion
For more information, visit: https://www.hypertherm.com
For more training, visit: https://www.hypertherm.com/HCI
Powermax Low Gas Pressure Faults for Powermax plasma systems under 50 amps
https://www.youtube.com/watch?v=jUFL5-kjOEo
Troubleshooting Powermax Low Gas Pressure Faults for Systems over 50A
https://www.youtube.com/watch?v=KmtqYi6-hhc
Troubleshooting Powermax 0-51 Fault: Start Signal at Power Up
https://www.youtube.com/watch?v=P1ciEWZbrOU
Troubleshooting Powermax Torch Cap Faults 0-50 Fault
https://www.youtube.com/watch?v=uaTiIz6fqpk
Powermax Preventive Maintenance
https://www.youtube.com/watch?v=iZcs03zKn0U