Powermax Pressure Faults for Systems Over 50 Amps

For metal workers who need to easily and reliably gouge and cut metal up to 38 mm (1-1/2″), Powermax® is a line of seven portable, professional-grade plasma systems that are designed for maximum productivity. Unlike other metal removal methods or competitive plasma brands, industry-leading Powermax systems allow customers to tackle any job by offering the most extensive manual and automated metal cutting and gouging capabilities.
This short video will help you to identify the symptoms of a low pressure error for the Powermax65, 85, 105, and 125 systems. It will also highlight where to locate the fault code on the machine and some of the possible solutions to this situation.
0:00 - Introduction
0:23 - Symptoms of the fault
0:42 - 0-12 Fault code
0:58 - Check the gas pressure gauge
1:31 - Gas test mode
2:35 - 0-20 Fault code
3:39 - Check for kinks, leaks, or restrictions in the gas line
3:55 - Inspect the air filter element
5:02 - Conclusion
For more information, visit: https://www.hypertherm.com
For more training, visit: https://www.hypertherm.com/HCI
You may also be interested in these other related video:
Troubleshooting a Powermax 0-30 fault code
https://www.youtube.com/watch?v=vQpLsep7Au4&t=0s
Powermax Low Gas Pressure Faults for Powermax plasma systems under 50 amps
https://www.youtube.com/watch?v=jUFL5-kjOEo&t=0s
Troubleshooting Powermax Low Gas Pressure Faults for Systems over 50A
Troubleshooting Powermax 0-51 Fault: Start Signal at Power Up
https://www.youtube.com/watch?v=P1ciEWZbrOU&t=0s
Powermax Preventive Maintenance
https://www.youtube.com/watch?v=iZcs03zKn0U&t=0s